![]() ![]() Jdbc:awsathena://UseResultsetStreaming=0 ProxyHost=localhost ProxyPort=port Protocol=http AwsRegion=us-any-1 UID=any PWD=any S3OutputLocation=s3://any/ Where it says any you can replace with any string, but a string must be there for proper functionality. When using the following JDBC drivers, we recommend entering the connection string directly. Some JDBC drivers have very specific connection string requirements. In this configuration, the user DOES need to specify a database, that is, any database that is accessible in the datasource, when connecting to the datasource via StrongDM. ![]() If the Override Database option is not enabled, the user will be able to change databases as normal.When a user connects to the datasource, they automatically connect to the database specified in the datasource configuration.In this configuration, the user does not need to specify a database when connecting to the datasource via StrongDM.If the user tries to change databases, the command appears to be successful but the user can only query the original datasource.When a user connects to the datasource, they are unable to change databases from the database configured in the datasource.However, this option works differently between SQL Server and PostgreSQL. The SQL Server and PostgreSQL datasource types, as well as PostgreSQL derivatives like Greenplum and Redshift, have the option of database overrides. SNOWSQL_PWD=none snowsql -u sdm -a sdm -d -s -w -h localhost -p port -D protocol=http PostgreSQL, Aurora PostgreSQL, Citus, Greenplum, Redshift MySQL, Aurora MySQL, MariaDB, SingleStore The known exceptions to both sets of values are as shown: Clientĭynamodb -endpoint-url Microsoft SQL Server Once added, go to the Driver Properties and set the portNumber to the StrongDM port-override value. Load a driver compatible with DB2 iseries, such as jt400-10.4.jar. Set any string for Account and false for SSL under Driver Propertiesįrom the Driver Properties settings, portNumber must be set to the SDM port-override value. See the JDBC Drivers section for information on how to use the Redshift JDBC driver. Use the edited config to connect via TinkerPop, and then open Gremlin Console: gremlin> :remote connect rver neptune-remote-sdm-graphson.yamlįor additional details, see the Connect to Oracle guide. To use Gremlin Console with Neptune, edit a configuration file for Neptune ( neptune-remote-sdm-graphson.yaml) to match the following: hosts: In addition, configure the client to use GraphSON instead of Gryo. SDM port should be separated by a comma with no spaces (for example, 127.0.0.1,11433) under Advanced… > Security set Trust server certificate to trueĬhange Network Protocol to TCP/IP Server Name should be the IP address SDM port should be separated by a comma with no spaces (for example, 127.0.0.1,11433)Ĭonfigure the client not to use TLS. ![]() Use system ODBC connection and SQL Server 10.x driver Aurora MySQL, Clustrix, MariaDB, MySQL, SingleStore #įor DataGrip, the Authentication field should be set as User & Password, not pgpass. The client’s form validation requires something to be written in that field, but the contents do not actually matter because the value is not used to make the connection. When the indicated value for a given field is empty, leave the field empty. This section lists some of the clients that require connection values that differ from the defaults.
0 Comments
Leave a Reply. |